Toombs County Blotter, Sims 4 Moonglow Lighting Mod, Articles P

It happens when the water temperature is above 135F while passing through the heat exchanger. Then reading how to fix the Pentair heater error code R13 guide will help you a lot. SuperFlo Pool Pump by Pentair Aquatic Systems is a direct replacement for the Hayward Super Pump Extremely quiet operation; Unionized fittings included (1-1/2 in. Make sure to see if there is any dirt blocking the air vents or exhaust and ensure all of these items are working. Using an extension cord or wiring to outlet is too light. It does this at all speeds not just one on setting. turn it off. So, if you have an older pool great performance. If adequate airflow via the blower is restored within 60 seconds after the problem message shows, the heater will resume normal performance. Now go to the breaker and turn the pump breaker off and then on again to reset the pump. Remove any obstructions. This means the motor was getting too hot. With extensive experience in pool repair and manufacturing, Press the button of the speed you have assigned to ensure that your unit runs with that speed. The Pentair heater error codes displayed in your heater display tell you that you need to address specific issues with your heater. Worst company I have ever dealt with by the way.Hope this helps someone. Make sure that your variable pump is on this means ensuring that the green power LED is turned on. You should not need to do any other troubleshooting unless the Err code does not clear after one or two resets. I've had an occasional bad drive out of the box. I will give it a try when I get home. Its possible that theres air in the pipes. Check to make sure the wire supplying . Pool pump choice: Jandy 1.85HP VS Pump vs. Pentair Superflo VST 2.2, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. When I give it power I immediately get the following error: F90052 ALARM! If you get really fine particle debris, you can insert a filter sock or filter saver in the skimmer basket to trap the smaller particle debris that can fit through the pump basket and enter the impeller. ERR SFS signifies the stack flue sensor on your heater has reached a temperature of more than 480F. cleared. When you notice the Pentair heater error code R13, you dont need to do anything because its merely a part of the startup routine. The pump is brand new and never used. codes will appear from time to time. The problem can be a malfunctioning blower fan or blockage of the fan air. You should be able to press the start/stop button to start up the pump. Here is what is going on. The cooling effectiveness of either a heat pump or an air conditioner can be improved by shading the exterior unit. The problem was that it happened so quickly you couldn't see what the error was. Are you checking the pump voltage when it is running? Thanks for the quick response. An ignition failure can be caused by a variety of heater components. Spin it completely around several times to make sure the blockage is cleared. At this point you may want to call out a pool RESOLUTION Deactivate then reactivate power to the heat pumpto clear error. ERR HLS Error Code 3. Otherwise, there could be excess voltage sag caused by improper installation or improper supply voltage. brand new pentair vs gives out code EOFF ,then shuts off . I got a new one from Pentair. one or two resets. Here's how, Shut off the whole system Troubleshoot the high-pressure issue causing the error. There are a number of reasons why your blower can stop working. It says "Err" and then "0002" and won't turn on. The Pentair SuperFlo Variable Speed pump is a great choice for a Variable Speed Pump. Speed 3 LED/button will select the third speed which is 2350 RPM. Remove cord connector from top of pump and dry out with cloth or hair dryer. clear the impeller jam the pump will start up and run like normal. The Err 0002 can also indicate a wire is loose in the pump or a poor connection. See page 14 Pump Disassembly for instructions for disassembling the pump. Then lost power last night for 8 hours. When the motor is stopped it is not drawing much current. Skimmer and Prevent Debris from Clogging the Pump! 001a Error code on Pentair Superflo VS pump. Hi, I installed a brand new pump. Looking at the case of the drive (where the ground screw attaches) you will notice that the seating surface for the ground wire is covered in powder coating. 27K views 1 year ago Videos on Heaters If your heater is displaying an eo5 or eo6 error code there is a simple fix. View our downloads here. Maybe thats why you initially mistook it for an error code. When your heaters ignition control module fails to fire up the heater, this error code will be on display. Press J to jump to the feed. Note: The IntelliFlo's internal anti-freeze protection is disabled when connected to an IntelliTouch system. I took mine apart (quite a pain) and there was nothing of interest there. I had pump running 24/7 due to freeze. As previously said, the Pentair heater error code R14 code isnt a cause for concern. Call the installer and have them check it out or have them get a warranty tech from Pentair to fix it. Save the speed you have chosen by pressing and holding the speed buttons to allocate that speed. If you had an installer do it, and you still have a warranty, i would call them out (because it is free) and tell them about this repair and see what they say. But more than likely when you clear the impeller jam the pump will start up and run like normal. ERR AFS Error Code 4. Your information will *never* be shared or sold to a 3rd party. Do you need a high pressure pump for spa jets and water features? through and into the pump impeller. So when the E03 error code comes up, you can conclude that your heater is burning. (The fan and impeller are on the same axle.) I then did each line separately and found out one wasn't connected to the double pull GFI breaker correctly. completely around several times to make sure the blockage is cleared. . filter sock or filter saver in the skimmer basket to trap the smaller particle You need to test each of the components to see if they are the culprit. It was never meant to be public, but looks like others are looking at this so i'll try to make it useful.I was having a problem with my pump where you could hear it reset itself for no reason. It will then begin to go into the priming mode and then start up. What exactly should I be looking for? Speed 1 LED/button will select the first speed which is 750 RPM. Go for the same solution as we have suggested for the E05 error code. In this section, we will look at what each error code means and what are the simple solutions for these errors. Go Back. The control board may also be the culprit and checking it with a multimeter should confirm it. To prevent the impeller from being clogged check your skimmer basket for debris and empty it when it becomes full. The FLO code indicates that the water flow to your heat pump has been halted by the filter pump. Commercial Pool Pump Savings Calculator; Pool TDH Calculator; Encompass Overview; Pro Mobile Apps; Membrane Filtration Tools. I'm guessing water is still frozen causing this? Error Code R14: Revision Mode 5. Any new postings here are unlikely to be seen or responded to by other members. Pentair X-Flow Xpert Web App; Aurora . try the above steps one more time and reset the pump again. To get rid of this error message, youll need to make sure theres enough water flowing. Check on the units wiring to ensure that isnt the problem. In that case, you can read our comprehensive guide on how to deal with Pentair heater error code R14. Clean the pool filter. Create an account to follow your favorite communities and start taking part in conversations. failsafe so that the pump doesnt overheat and become damaged. Spin it TradeGrade products must be purchased from a retail store (brick & mortar), pool builder or pool service company to receive a one-year, two-year or three-year warranty. Doing this may free the blockage. The pump ran fine yesterday. debris that can fit through the pump basket and enter the impeller. Ooops. If they do not clear after multiple restart attempts, the drive should undergo a hard power cycle. My ended up smelling nicely burnt in the control/drive. If it is connected at the skimmer you may want to try the after-market Hole in One Basket for the skimmer. The most common one is the Err 0002 and it is usually caused by the impeller getting clogged and the pump is unable to prime. Very low pH and alkalinity levels over several years can strip the copper from a heat exchanger and wear the tube walls paper thin.Saltwater pools can also develop corrosion around fin welds, which could . The thermal regulator must be in good functioning order and in the correct position. on a single 110V breaker the SuperFlo VS pump is pretty much the only Variable We are a registered 501(c)3 non-profit that is funded by user donations. And in that case, the common error codes with your Pentair MasterTemp are ERR PS, ERR HLS, ERR AFS, ERR IGN, ERR AGS, ERR SFS, E01, E05, and E06. If your igniter doesnt spark, it is faulty and needs replacement. Otherwise, the temperature sensor may be faulty. Disconnect power to the pump and wait until the keypad LEDs have all turned off. If necessary, clean the heat exchanger. connected to the pool, make sure you are using an in-line leaf canister. It means that the SFS has shorted. Learn more Shop Now Pentair - EC-011059 - IntelliFlo i1 Variable Speed Pool Pump - Limited Warranty $1,859.00 Press and hold the four buttons simultaneously for about 4 seconds. Pentair IntelliFlo3 VSF 3.0HP with I/O Board, Youtech - Home Services Digital Marketing Agency. It could be a bad drive but that is not common. Family-owned and operated, our company has dedicated over 25 years of exceptional service. I like the fact that it can down convert the voltage and be used at 120V as well as at 230V. They mean the same. Disclaimer, if you chose to do this it is at your own risk. Press question mark to learn the rest of the keyboard shortcuts. Possible causes include incorrect wiring, dirt and debris obstruction, a lack of power supply, a defective ignition control module, and so on. Pentair Heater Error Codes [Reasons + Solutions] 1. RESOLUTION Pentair Pool Pumps 10 Results Reset Horsepower Voltage Pentair - EC-342001 - SuperFlo VS Variable Speed Pool Pump, 1.5 HP - Limited Warranty $1,269.00 Buy in monthly payments with Affirm on orders over $50. The time it takes a heat pump to heat a pool is determined by a few factors. You would think the ground screw would be conductive enough but it turns out that green coating has a ton of resistance and prevents you from getting a good ground.So I carefully removed the powder coating under that ground screw and reconnected everything and my resistance went to 0 ohm on the ground line indicating a perfect path to ground. I originally. The Ran fine all summer. I figure after looking at this dissassembled you could tell if it was impeded by some cruft in the impeller by trying to turn it manually. Any new postings here are unlikely to be seen or responded to by other members. Followed instructions on page 14 of manual. Read our article on Pentair ignition failure to learn more. What it means:refrigerant systems high-pressure switch is open, What it means:refrigerant systems low-pressure switch is open, What it means:5 faults have occurred within the heat pumps last cycle, Medallion Energy 3055 Tech Park Way Deland, FL 32724 407-786-0000, Hours Mon-Fri: 8am 7pm Saturday: 9am 5pm Sunday: By Appointment, Service Areas Anywhere in the United States and throughout Florida.Orlando, Longwood, Miami, Tampa Bay, Jacksonville, St Cloud, Tallahassee, Daytona Beach, Davenport, Windermere, Clearwater, and the rest of North, South, and Central Florida. Pentair Superflo VS Variable Speed Pump Err 02 code, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Make sure that the pump is on by ensuring that the LED power is on. Variable speed pumps move water more efficiently at lower speeds, saving money and energy. I got that a few times the other day while backwashing but the pump Would kick on a second or two later. Anti-freezing: When active, the motor will run at 1000 rpm for 60 minutes. If the Err 0002 code is still on the screen, try the above steps one more time and reset the pump again. It would self prime in about 1 minute and everything was happy. This is caused by insufficient water flow through the heater. As an industry leader, we're proud of the innovative designs and exceptional efficiency our inground pool pumps can offer. The pump ran fine yesterday. I installed a new Superflo VS pump on my 16x36 inground pool. Pentair heaters sometimes display codes R13 and R14. start/stop button to start up the pump. If you have a suction side cleaner This can very easily be checked. WARNING: Any troubleshooting that involves electrical work is dangerous, and should be performed by a professional pool heater repair tech. Is it possible the motor is getting a lot of resistance and pulling too much current? is connected at the skimmer you may want to try the after-market Hole in One Basket Does anyone know why it would cut off like this? The Pentair SuperFlo Variable Speed pump is a great choice for a Variable Speed Pump. If you see that your SuperFlo VS is not running as You must check that the rate of water flow is within the range specified and that the water temperature does not exceed 140F to correct this error. It was scheduled to come on at 7am this morning and now its throwing the 001a error code. If you get really fine particle debris, you can insert a Pentair vs superflow model350879.A error code A1. service professional to trouble shoot the pump. If the above does not work you will need to have the pump and connections tested with a multimeter to see where the short is. Ensure that the 5 pin connector is properly plugged into the socket and that there is no damage to the cable. Yes, it is necessary. Any comments on this would be great. Its like not insulating your houses loft if you dont utilize a sun cover. AFS stands for airflow switch. If you have any questions regarding Pentair gas pool heater error codes, you can leave us a comment. All of these occurrences are out of the ordinary. Heat pump troubleshooting guide for Pentair pool heaters. But like anything electronic running from software, error Some Tips for Manually Vacuuming Your Swimming Pool. And remember, you must ensure that the water flow is not obstructed. It will then begin to go into the The error code E03 means that the thermal fuse of the STA-RITE is open. Error Code AD0: Bad Keypad 6. At this point, reconnect power to the pump. Pentair heat pump error code LOW WATER FLOW LOW WATER FLOW What it means: the unit's low-pressure switch senses that water flow is open or low How to fix it: Check that pool pump is sending water to heater Ensure that pool pump is receiving enough water Check that your pool system's multiport valves are on the correct settings Error Code ERR PS: Water Pressure Switch Is Open 7. When your pressure switch is stuck open, you will find the Pentair pool heater error code PS on your heater display. Error Codes Key for Pentair Superflo VS Pump These codes are a great way to do a simple diagnostic to see what issues your pump is having. I am new to the Forum but have loved the advice and guidance I have received through here for the last two years. For a better experience, please enable JavaScript in your browser before proceeding. voltage and be used at 120V as well as at 230V. It will then begin to go into the priming mode and then start up. Benefits of a Pentair Variable Speed Pool Pump Higher Performance Consistent flow control for the highest energy saving and ultimate system performance. Create an account to follow your favorite communities and start taking part in conversations. (Save $300+!) Energy & Cost Savings Slow and steady wins the race. Power off the unit and restart. If the pump isnt running, press the start button to power it on. Now, every morning when is scheduled to turn on, it shoots out error codes 0002 and 000F. My family and friends were all swimming this past weekend with no issues. New Pentair pump giving error codes 0002 and 000F Hi, I recently replaced my pool motor and had my new VS SuperFlo working for about 1-2 weeks. Looking that up I found that this indicated an "Absolute Diode Bridge temperature limit exceeded". JavaScript is disabled. When your heater is turned on, youll see this code on the display. In ERR PS, the PS stands for the pressure switch. The screen will display an error code as Err and then display a number. Your heaters ignition control module is the most likely culprit that will need to be replaced. for the skimmer. I set up a gopro for hours and finally caught it giving and error 0021.Pentair was an absolute disaster to deal with but i was finally able to get them to send me a new drive. I can make it work if I take an Allen wrench and manually spin the impeller for a few rotations. I tried hard resetting and turning off power for multiple minutes. Capacitor Replacement and Troubleshooting! Power Out/OFF Does anyone knows what this means? Insufficient water flow is usually caused by a dirty filter. Error Code E05: Stack Flue Sensor Is Open 2. Also make sure both the skimmer 21 -Communication link between HMI and motor control has been lost. jammed in there. Ecommerce (EC) products: Products purchased from an Authorized Pentair . When the temperature of the water going through the heat exchanger for the second time exceeds 140F, the Pentair pool heater error code AGS occurs. When R13 is still displayed, your Pentair heaters service light may turn on. The Hole in One Basket: Connect a Cleaner at the Skimmer and Prevent Debris from Clogging the Pump! ERR SFS Error Code 7. Pentair Heat Exchanger Troubleshooting: The biggest fear about the heat exchanger is that corrosion can occur to the relatively soft copper finned tubes, causing them to develop pinhole leaks. So, if you have an older pool on a single 110V breaker the SuperFlo VS pump is pretty much the only Variable Speed Pump that you can install. This is because, after 60 seconds of mistake, the heater will enter lockout mode. insert it into the back of the pump. I have an error code on my Pentair variable speed pump. This is totally a manufacturing problem on pentair's end. What would be the cause of that? I like the fact that it can down convert the voltage and be used at 120V as well as at 230V. You can easily assign up to four new speeds. Freeze protection is provided by selecting YES at the ON WITH FREEZE this may free the blockage. The Pentair SuperFlo Variable Speed pump is a great Use the following troubleshooting guide to repair common heat pump issues and get technical support. will no longer show the Err 0002 code. If the Err 0002 code is still on the screen, try the above steps one more time and reset the pump again. We will break down why these codes appear. The manual states that I should disassemble the pump and check the impeller and seal plate. Riptide Vacuum System Steering Knuckle Upgrade! All rights reserved. How long does a Pentair pool heater take to heat a pool? I originally posted it only so the folks at pentair could see it and totally forgot about it. : https://youtu.be/huAt9BXLu9ISuperFlo VS Playlist: https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzPVisit my Website: http://www.swimmingpoollearning.com/eBook: https://www.swimmingpoollearning.com/swimming-pool-care-ebookYouTube Video Index: http://poolmandave.blogspot.com/2014/03/swimming-pool-tips-reviews-how-to-video.html A list of all of my videos.Follow Me:Google +: https://plus.google.com/+MrDgvb1/postsBlogger: http://poolmandave.blogspot.com/ Facebook: https://www.facebook.com/pages/Youtube-Mrdgvb1/381257741926763?ref=hl Twitter: https://twitter.com/Mrdgvb1Join me on Patreon: https://www.patreon.com/poolguycoachingPodcast: http://www.buzzsprout.com/110832Podcast Website: https://www.thepoolguypodcastshow.com/Coaching Site: https://poolguycoaching.com/Shop INYOPools: www.inyopools.com?utm_source=youtube\u0026utm_medium=swimming-pool-tips